Reference product range for solar cables, organized for technical comparison and project enquiries.
Open Air, Buried, In conduit
Key product information for comparison, engineering review and quotation preparation.
Reference specification for PV AL 1500V in the Solar Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
| Material | Aluminium, class 2 |
|---|---|
| Conductor | Aluminium, class 2 according to EN 60228 and IEC 60228 |
| Insulation | Cross-linked polyethylene (XLPE), type XLPE according to IEC 60502-1 |
| Outer Sheath | Special UV resistant PVC, type ST2 according to IEC 60502-1. Black colour |
| Rated Voltage | 1.5/1.5 (1.8) kV DC / 1.8/3 (3.6) kV AC |
| Maximum Conductor Temperature | 90 °C |
| Maximum Short-Circuit Temperature | 250 (max. 5 s) °C |
| Minimum Service Temperature | -40 (fixed and protected installations) °C |
| Minimum Installation Temperature | 0 (on cable surface) °C |
| Flame Non-Propagation | Flame non-propagation according to EN 60332-1 and IEC 60332-1 |
| CPR Classification | Eca according to EN 50575 |
| Reduced Halogens | Reduced halogen emission. Chlorine < 15% |
| Minimum Bending Radius | 5x cable diameter |
| Impact Resistance | AG3 High severity |
| Chemical & Oil Resistance | Good |
| UV Resistance | Yes, according to EN 50618 and HD 605/A1 |
| Water Resistance | AD8 Submersion |
| Installation Conditions | Open Air, Buried, In conduit |
| Standards (According To) | IEC 60502-1, EN 50618 |
| Standards and Approvals | CE, RoHS, RETIE |
| Typical Applications | PV plants, Industrial facilities, Power distribution |
| Value Proposition 1 | Aluminium conductor — significant weight and cost reduction vs copper for long DC feeder runs |
| Value Proposition 2 | 1500 V DC rated — future-proof design for high-voltage string architectures |
| Value Proposition 3 | IEC 60502-1 and EN 50618 compliant — meets international solar cable standards |
| Value Proposition 4 | UV, water (AD8) and chemical resistant — engineered for harsh outdoor environments |
| Value Proposition 5 | Versatile installation — suitable for open air, buried and in conduit applications |
| Value Proposition 6 | Operating range -40 °C to 90 °C — reliable performance in extreme climates |
| Value Proposition 7 | CE, RoHS and RETIE certified — regulatory compliance for European and Latin American markets |
Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.
Use-case guidance to understand where this product fits best.
Reference application: Open Air.
Reference application: Buried.
Reference application: In conduit.
Service and manufacturing advantages that support the product decision.
Stable manufacturing and dependable delivery quality.
Practical cable solutions for project-specific use cases.
Balanced cost and product performance for long-term projects.
Fast response before delivery and after project deployment.
Use these quick answers to help technical and commercial teams align faster.
Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.
Where the source provides a public datasheet, use the download button and verify that it is the current revision.
Send the reference model and project requirements to the sales team for an equivalent-product review and quotation.
Reference specification for PV LSZH AL 1500V in the Solar Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for H1Z2Z2-K in the Solar Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for PV AL 1500V in the Solar Cables range. Confirm final construction, standards and sizing for the actual project before ordering.