TOPDRIVE® VFD EMC ROZ1-K 0.6/1kV

Reference specification for ROZ1-K (AS) 0.6/1kV in the Marine Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

Open Air, Buried, In conduit

Category Marine Cables
Brand TOPDRIVE® (reference)
Voltage 0.6/1 kV
Conductor Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
Standards IEC 60502-1, IEC 60092-353
Applications Open Air, Buried, In conduit
Updated 2026-07-28

Technical overview

Key product information for comparison, engineering review and quotation preparation.

Product description

Reference specification for ROZ1-K (AS) 0.6/1kV in the Marine Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

MaterialCopper, class 5 (flexible)
ConductorElectrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
InsulationCross-linked polyethylene type XLPE according to IEC 60502-1, type HF XLPE 90°C according to IEC 60092-360
Outer SheathPolyolefin type ST8 according to IEC 60502-1 and type SHF1 according to IEC 60092-360
Rated Voltage0.6/1 kV
Maximum Conductor Temperature90 °C
Maximum Short-Circuit Temperature250 (max. 5 s) °C
Minimum Service Temperature-40 (fixed and protected installations) °C
Minimum Installation Temperature0 (on cable surface) °C
Flame Non-PropagationFlame non-propagation according to EN 60332-1 / IEC 60332-1
Fire Non-PropagationFire non-propagation according to EN 60332-3 / IEC 60332-3 and EN 50399
CPR ClassificationCca-s1a, d1, a1 according to EN 50575
Halogen FreeLow Smoke Halogen Free according to EN 60754-1 / IEC 60754-1
Low Corrosive Gases EmissionLow corrosive gases emission according to EN 60754-2 / IEC 60754-2
Low Smoke EmissionLow smoke emission according to EN 61034 / IEC 61034
Light Transmittance> 80%
Minimum Bending Radius10x cable diameter
Impact ResistanceAG2 Medium severity
Chemical & Oil ResistanceAcceptable
UV ResistanceUV Resistant according to EN 50618
Water ResistanceAD5 Jets
Installation ConditionsOpen Air, Buried, In conduit
Standards (According To)IEC 60502-1, IEC 60092-353
Standards and ApprovalsBUREAU VERITAS, DNV-GL, ABS, LLOYD'S REGISTER, RoHS, CE
Typical ApplicationsVariable Frequency Drives, Industrial motors, Pumps, EMC sensitive installations

Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.

Key characteristics

Electrical performance 0.6/1 kV
Conductor Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
Standards IEC 60502-1, IEC 60092-353
Applications Open Air, Buried, In conduit
Visits 1

Typical applications

Use-case guidance to understand where this product fits best.

TOPDRIVE® VFD EMC ROZ1-K 0.6/1kV

Open Air

Reference application: Open Air.

TOPDRIVE® VFD EMC ROZ1-K 0.6/1kV

Buried

Reference application: Buried.

TOPDRIVE® VFD EMC ROZ1-K 0.6/1kV

In conduit

Reference application: In conduit.

Why choose this cable

Service and manufacturing advantages that support the product decision.

Quality

Quality

Stable manufacturing and dependable delivery quality.

Engineering

Engineering

Practical cable solutions for project-specific use cases.

Value

Value

Balanced cost and product performance for long-term projects.

Support

Support

Fast response before delivery and after project deployment.

Product FAQs

Use these quick answers to help technical and commercial teams align faster.

Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.

Questions? We help you select the right cable.
Technical support

Questions? We help you select the right cable.

Request a quote

Related products