| Material | Copper, class 5 (flexible) |
|---|---|
| Conductor | Copper, class 5 (flexible) according to IEC 60228 |
| Protective Conductor | Ground conductor divided into three conductors; equivalent cross-section approximately 50% of phase conductor (4G cables have equal cross-section) |
| Insulation | Cross-linked polyethylene type XLPE according to IEC 60502-1 |
| Screen | Overlapping aluminum-polyester tape screen with 100% coverage + tinned copper drain wire |
| Outer Sheath | Polyolefin LSZH according to IEC 461-05-04 |
| Rated Voltage | 0.6/1 kV |
| Maximum Conductor Temperature | 90 °C |
| Maximum Short-Circuit Temperature | 250 (max. 5 s) °C |
| Maximum Ambient Temperature | 60 °C |
| Minimum Service Temperature | -40 (fixed and protected installations) °C |
| Minimum Installation Temperature | 0 (on cable surface) °C |
| Flame Non-Propagation | Flame non-propagation according to EN 60332-1 / IEC 60332-1 |
| CPR Classification | Cca-s1a, d1, a1 according to EN 50575 |
| Halogen Free | Low Smoke Halogen Free according to IEC 60754-1 |
| Low Smoke Emission | Low smoke emission, light transmittance > 80% |
| Minimum Bending Radius | 10x cable diameter |
| Impact Resistance | AG2 Medium severity |
| Chemical & Oil Resistance | Acceptable |
| UV Resistance | UV Resistant according to EN 50618 |
| Water Resistance | AD5 Jets |
| Installation Conditions | Open Air, Buried, In conduit |
| Standards (According To) | IEC 60502-1, IEC 60092-353 |
| Standards and Approvals | BUREAU VERITAS, DNV-GL, ABS, LLOYD'S REGISTER, RoHS, CE |
| Typical Applications | Variable Frequency Drives, Industrial motors, Pumps, EMC sensitive installations |
Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.
Use-case guidance to understand where this product fits best.
Reference application: Open Air.
Reference application: Buried.
Reference application: In conduit.
Service and manufacturing advantages that support the product decision.
Stable manufacturing and dependable delivery quality.
Practical cable solutions for project-specific use cases.
Balanced cost and product performance for long-term projects.
Fast response before delivery and after project deployment.
Use these quick answers to help technical and commercial teams align faster.
Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.
Where the source provides a public datasheet, use the download button and verify that it is the current revision.
Send the reference model and project requirements to the sales team for an equivalent-product review and quotation.
Reference specification for XZ1-K in the Marine Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for 2XSL(ST)CH in the Marine Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for ROZ1-K (AS) 0.6/1kV in the Marine Cables range. Confirm final construction, standards and sizing for the actual project before ordering.