Reference product range for armoured cables, organized for technical comparison and project enquiries.
Open Air. Buried. In conduit.
Key product information for comparison, engineering review and quotation preparation.
Reference specification for RZ1MZ1-K in the Armoured Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
| Material | Copper, class 5 (flexible) |
|---|---|
| Conductor | Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228 |
| Insulation | Cross-linked polyethylene type XLPE according to IEC 60502-1 |
| Separation Sheath / Bedding | Low smoke halogen free polyolefin |
| Armour | Galvanized steel wire armour. |
| Outer Sheath | Low smoke halogen free polyolefin. Black colour |
| Rated Voltage | 0.6/1 kV |
| Maximum Conductor Temperature | 90 °C |
| Maximum Short-Circuit Temperature | 250 (max. 5 s) °C |
| Minimum Service Temperature | -50 °C |
| Minimum Installation Temperature | 0 °C |
| Flame Non-Propagation | Flame non-propagation according to EN 60332-1 / IEC 60332-1 |
| CPR Classification | Cca-s1b, d1, a2 according to EN 50575 |
| Halogen Free | Halogen free according to EN 60754-1 / IEC 60754-1 |
| Low Corrosive Gases Emission | Low corrosive gases emission according to EN 60754-2 / IEC 60754-2 |
| Low Smoke Emission | Low smoke emission according to UNE-EN 61034 / IEC 61034 |
| Light Transmittance | > 60% |
| Minimum Bending Radius | 10x cable diameter |
| Impact Resistance | AG4 High severity |
| Rodent Proof | Rodent proof |
| Chemical & Oil Resistance | Good |
| UV Resistance | UV Resistant according to EN 50618 |
| Hydrocarbon Resistance | Hydrocarbon resistant |
| Water Resistance | AD5 Jets |
| ATEX | Suitable for ATEX explosive atmospheres according to ITC-BT 29 |
| Installation Conditions | Open Air. Buried. In conduit. |
| Standards (According To) | IEC 60502-1 |
| Standards and Approvals | AENOR, RoHS, CE |
| Typical Applications | Industrial facilities, ATEX zones, Power distribution |
Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.
Use-case guidance to understand where this product fits best.
Reference application: Open Air. Buried. In conduit..
Reference application: Armoured Cables.
Reference application: Armoured Cables.
Service and manufacturing advantages that support the product decision.
Stable manufacturing and dependable delivery quality.
Practical cable solutions for project-specific use cases.
Balanced cost and product performance for long-term projects.
Fast response before delivery and after project deployment.
Use these quick answers to help technical and commercial teams align faster.
Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.
Where the source provides a public datasheet, use the download button and verify that it is the current revision.
Send the reference model and project requirements to the sales team for an equivalent-product review and quotation.
Reference specification for RVFV-K in the Armoured Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for RZ1MZ1-K in the Armoured Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for RVhMVh-K in the Armoured Cables range. Confirm final construction, standards and sizing for the actual project before ordering.