Henan Donglian Cable Co., Ltd.
Armoured Cables
Cables

Armoured Cables

Reference product range for armoured cables, organized for technical comparison and project enquiries.

Armoured Cables

POWERHARD® M RVhMVh-K

Reference specification for RVhMVh-K in the Armoured Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

Open Air. Buried. In conduit.

Category Armoured Cables
Brand POWERHARD® (reference)
Voltage 0.6/1 kV
Conductor Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
Standards IEC 60502-1
Applications Open Air. Buried. In conduit.
Updated 2026-07-28

Technical overview

Key product information for comparison, engineering review and quotation preparation.

Product description

Reference specification for RVhMVh-K in the Armoured Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

MaterialCopper, class 5 (flexible)
ConductorElectrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
InsulationCross-linked polyethylene type XLPE according to IEC 60502-1
Inner CoveringPVC
ArmourGalvanized steel wire armour.
Outer SheathPVC (flexible). Black colour
Rated Voltage0.6/1 kV
Maximum Conductor Temperature90 °C
Maximum Short-Circuit Temperature250 (max. 5 s) °C
Minimum Service Temperature-40 (fixed and protected installations) °C
Minimum Installation Temperature0 °C
Flame Non-PropagationFlame non-propagation according to EN 60332-1 / IEC 60332-1
CPR ClassificationEca according to EN 50575
Reduced HalogensReduced halogens, Chlorine < 15%
Minimum Bending Radius10x cable diameter (during installation)
Impact ResistanceAG4 High severity
Rodent ProofRodent proof
Chemical & Oil ResistanceGood
UV ResistanceUV Resistant according to UNE 211605
Water ResistanceAD7 Immersion
Installation ConditionsOpen Air. Buried. In conduit.
Standards (According To)IEC 60502-1
Standards and ApprovalsBUREAU VERITAS, RoHS, CE
Typical ApplicationsIndustrial facilities, Outdoor lighting, Underground installations, ATEX zones

Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.

Key characteristics

Electrical performance 0.6/1 kV
Conductor Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
Standards IEC 60502-1
Applications Open Air. Buried. In conduit.
Visits 1

Typical applications

Use-case guidance to understand where this product fits best.

POWERHARD® M RVhMVh-K

Open Air. Buried. In conduit.

Reference application: Open Air. Buried. In conduit..

POWERHARD® M RVhMVh-K

Armoured Cables

Reference application: Armoured Cables.

POWERHARD® M RVhMVh-K

Armoured Cables

Reference application: Armoured Cables.

Why choose this cable

Service and manufacturing advantages that support the product decision.

Quality

Quality

Stable manufacturing and dependable delivery quality.

Engineering

Engineering

Practical cable solutions for project-specific use cases.

Value

Value

Balanced cost and product performance for long-term projects.

Support

Support

Fast response before delivery and after project deployment.

Product FAQs

Use these quick answers to help technical and commercial teams align faster.

Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.

Questions? We help you select the right cable.
Technical support

Questions? We help you select the right cable.

Request a quote

Related products

Previous: 没有了! Next: TOXFREE® LSZH RZ1MZ1-K