Henan Donglian Cable Co., Ltd.
Rubber Cables
Cables

Rubber Cables

Reference product range for rubber cables, organized for technical comparison and project enquiries.

Rubber Cables

XTREM® DN-F 0,6/1 kV

Reference specification for DN-F in the Rubber Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

Open Air. Submersible pumps cable

Category Rubber Cables
Brand XTREM® (reference)
Voltage 0.6/1 kV
Conductor Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
Standards UNE 21150
Applications Open Air. Submersible pumps cable
Updated 2026-07-28

Technical overview

Key product information for comparison, engineering review and quotation preparation.

Product description

Reference specification for DN-F in the Rubber Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

MaterialCopper, class 5 (flexible)
ConductorElectrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
InsulationThermosetting rubber (flexible) according to UNE 21150
Outer SheathThermosetting flexible rubber. Black colour
Rated Voltage0.6/1 kV
Maximum Conductor Temperature90 °C
Maximum Short-Circuit Temperature250 (max. 5 s) °C
Minimum Service Temperature-40 (fixed and protected installations) and -25 (mobile use) °C
Flame Non-PropagationFlame non-propagation according to EN 60332-1 / IEC 60332-1
CPR ClassificationEca according to EN 50575
Minimum Bending Radius3x cable diameter < 12 mm, 4x cable diameter ≥ 12 mm
Impact ResistanceAG2 Medium severity
Chemical & Oil ResistanceExcellent. Grease & mineral oils resistance: Excellent
UV ResistanceUV Resistant according to EN 50618
Water ResistanceAD8 Submersion
Installation ConditionsOpen Air. Submersible pumps cable
Standards (According To)UNE 21150
Standards and ApprovalsRoHS, CE
Typical ApplicationsIndustrial facilities, Transportable machines, Agricultural applications

Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.

Key characteristics

Electrical performance 0.6/1 kV
Conductor Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
Standards UNE 21150
Applications Open Air. Submersible pumps cable
Visits 1

Typical applications

Use-case guidance to understand where this product fits best.

XTREM® DN-F 0,6/1 kV

Open Air. Submersible pumps cable

Reference application: Open Air. Submersible pumps cable.

XTREM® DN-F 0,6/1 kV

Rubber Cables

Reference application: Rubber Cables.

XTREM® DN-F 0,6/1 kV

Rubber Cables

Reference application: Rubber Cables.

Why choose this cable

Service and manufacturing advantages that support the product decision.

Quality

Quality

Stable manufacturing and dependable delivery quality.

Engineering

Engineering

Practical cable solutions for project-specific use cases.

Value

Value

Balanced cost and product performance for long-term projects.

Support

Support

Fast response before delivery and after project deployment.

Product FAQs

Use these quick answers to help technical and commercial teams align faster.

Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.

Questions? We help you select the right cable.
Technical support

Questions? We help you select the right cable.

Request a quote

Related products