Reference product range for medium voltage cables, organized for technical comparison and project enquiries.
Open Air. In conduit. Underground. Submerged.
Key product information for comparison, engineering review and quotation preparation.
Reference specification for TSLF AL in the Medium Voltage Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
| Material | Aluminium, class 2 |
|---|---|
| Conductor | Aluminium, class 2 according to EN 60228 and IEC 60228 |
| Conductor Screen | Cross-linked semiconductor, triple extrusion |
| Insulation | XLPE, triple layer extrusion |
| Insulation Screen | Cross-linked semiconductor, bonded to insulation |
| Metallic Screen | Copper wires over swellable tape |
| Water Blocking | Aluminium foil/polymer laminate radial barrier |
| Outer Sheath | Polyethylene. Black colour |
| Rated Voltage | 12/20 to 18/30 kV |
| Maximum Conductor Temperature | 90 °C |
| Maximum Short-Circuit Temperature | 250 (max. 5 s) °C |
| Minimum Service Temperature | -15 °C |
| CPR Classification | Eca according to EN 50575 |
| Halogen Free | Halogen free according to EN 60754-1 and IEC 60754-1 |
| Low Corrosive Gases Emission | Low corrosive gases emission according to EN 60754-2 and IEC 60754-2 |
| Minimum Bending Radius (Installed) | 15x cable diameter |
| Minimum Bending Radius (During Installation) | 30x cable diameter |
| Water Resistance | AD8 Submersion |
| Installation Conditions | Open Air. In conduit. Underground. Submerged. |
| Standards (According To) | HD 620-10K |
| Standards and Approvals | CE, RoHS |
| Typical Applications | Nordic distribution networks, Nordic industrial facilities, Nordic street lighting |
Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.
Use-case guidance to understand where this product fits best.
Reference application: Open Air. In conduit. Underground. Submerged..
Reference application: Medium Voltage Cables.
Reference application: Medium Voltage Cables.
Service and manufacturing advantages that support the product decision.
Stable manufacturing and dependable delivery quality.
Practical cable solutions for project-specific use cases.
Balanced cost and product performance for long-term projects.
Fast response before delivery and after project deployment.
Use these quick answers to help technical and commercial teams align faster.
Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.
Where the source provides a public datasheet, use the download button and verify that it is the current revision.
Send the reference model and project requirements to the sales team for an equivalent-product review and quotation.
Reference specification for RHVhMVh 3x Cu +H1 in the Medium Voltage Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for RHZ1 AL OL/2OL in the Medium Voltage Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for RHZ1 (S) AL OL/2OL in the Medium Voltage Cables range. Confirm final construction, standards and sizing for the actual project before ordering.