Reference specification for RZ1FZ1-K in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
| Material | Copper, class 5 (flexible) |
|---|---|
| Conductor | Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228 |
| Insulation | Cross-linked polyethylene type XLPE according to IEC 60502-1 |
| Separation Sheath / Bedding | Low smoke halogen free polyolefin |
| Armour | Double steel or aluminium tape armour. Aluminium armour is used in single-core cables to avoid parasite currents that may overheat the cable |
| Outer Sheath | Low smoke halogen free polyolefin. Green colour |
| Rated Voltage | 0.6/1 kV |
| Maximum Conductor Temperature | 90 °C |
| Maximum Short-Circuit Temperature | 250 (max. 5 s) °C |
| Minimum Service Temperature | -40 (fixed and protected installations) °C |
| Flame Non-Propagation | Flame non-propagation according to EN 60332-1 / IEC 60332-1 |
| Fire Non-Propagation | Fire non-propagation according to EN 60332-3 / IEC 60332-3 and EN 50399 |
| CPR Classification | Cca-s1b, d1, a1 according to EN 50575 |
| Halogen Free | Halogen free according to EN 60754-1 / IEC 60754-1 |
| Low Corrosive Gases Emission | Low corrosive gases emission according to UNE-EN 60754-2 / IEC 60754-2 |
| Low Smoke Emission | Low smoke emission according to EN 61034 / IEC 61034 |
| Light Transmittance | > 60% |
| Minimum Bending Radius | 10x cable diameter (during installation) |
| Impact Resistance | AG4 High severity |
| Rodent Proof | Rodent proof |
| Chemical & Oil Resistance | Acceptable |
| UV Resistance | UV Resistant according to EN 50618 |
| Water Resistance | AD5 Jets |
| Installation Conditions | Open Air. Buried. In conduit. |
| Standards (According To) | IEC 60502-1, UNE 21123-4 |
| Standards and Approvals | RoHS, CE |
| Typical Applications | High-occupancy buildings, Industrial facilities, Power distribution |
Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.
Use-case guidance to understand where this product fits best.
Reference application: Open Air. Buried. In conduit..
Reference application: LSZH Cables.
Reference application: LSZH Cables.
Service and manufacturing advantages that support the product decision.
Stable manufacturing and dependable delivery quality.
Practical cable solutions for project-specific use cases.
Balanced cost and product performance for long-term projects.
Fast response before delivery and after project deployment.
Use these quick answers to help technical and commercial teams align faster.
Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.
Where the source provides a public datasheet, use the download button and verify that it is the current revision.
Send the reference model and project requirements to the sales team for an equivalent-product review and quotation.
Reference specification for N2XH in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for N2XH flex 1,8/3kV in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for YMz1Kf in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.