Henan Donglian Cable Co., Ltd.
LSZH Cables
Cables

LSZH Cables

Reference product range for lszh cables, organized for technical comparison and project enquiries.

LSZH Cables

TOXFREE® LSZH RZ1 AL

Reference specification for RZ1 AL in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

Open Air, Buried, In conduit

Category LSZH Cables
Brand TOXFREE® (reference)
Voltage 0.6/1 kV
Conductor Aluminium, class 2 according to EN 60228 and IEC 60228
Standards IEC 60502-1
Applications Open Air, Buried, In conduit
Updated 2026-07-28

Technical overview

Key product information for comparison, engineering review and quotation preparation.

Product description

Reference specification for RZ1 AL in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

MaterialAluminium, class 2
ConductorAluminium, class 2 according to EN 60228 and IEC 60228
InsulationCross-linked polyethylene (XLPE) according to IEC 60502-1
Outer SheathPolyolefin LSZH. Green colour
Rated Voltage0.6/1 kV
Maximum Conductor Temperature90 °C
Maximum Short-Circuit Temperature250 (max. 5 s) °C
Minimum Service Temperature-40 (fixed and protected installations) °C
Minimum Installation Temperature0 (on cable surface) °C
Flame Non-PropagationFlame non-propagation according to EN 60332-1 and IEC 60332-1
Fire Non-PropagationFire non-propagation according to EN 60332-3 and IEC 60332-3 and EN 50399
CPR ClassificationB2ca-s1a,d1,a1 (single-core) or B2ca-s1b,d1,a1 (multicore) according to EN 50575
Halogen FreeHalogen free according to IEC 60754-1
Low Corrosive Gases EmissionLow corrosive gases emission according to EN 60754-2 and IEC 60754-2
Low Smoke EmissionLow smoke emission according to EN 61034 and IEC 61034
Light Transmittance> 60%
Minimum Bending Radius5x cable diameter
Impact ResistanceAG2 Medium severity
Chemical & Oil ResistanceAcceptable
UV ResistanceYes, according to UNE 211605 and EN 50618
Water ResistanceAD8 Submersion
Installation ConditionsOpen Air, Buried, In conduit
Standards (According To)IEC 60502-1
Standards (Based On)UNE 21123-4
Standards and ApprovalsCE, RoHS
Typical ApplicationsPower distribution, Industrial facilities, Buried PV installations

Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.

Key characteristics

Electrical performance 0.6/1 kV
Conductor Aluminium, class 2 according to EN 60228 and IEC 60228
Standards IEC 60502-1
Applications Open Air, Buried, In conduit
Visits 1

Typical applications

Use-case guidance to understand where this product fits best.

TOXFREE® LSZH RZ1 AL

Open Air

Reference application: Open Air.

TOXFREE® LSZH RZ1 AL

Buried

Reference application: Buried.

TOXFREE® LSZH RZ1 AL

In conduit

Reference application: In conduit.

Why choose this cable

Service and manufacturing advantages that support the product decision.

Quality

Quality

Stable manufacturing and dependable delivery quality.

Engineering

Engineering

Practical cable solutions for project-specific use cases.

Value

Value

Balanced cost and product performance for long-term projects.

Support

Support

Fast response before delivery and after project deployment.

Product FAQs

Use these quick answers to help technical and commercial teams align faster.

Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.

Questions? We help you select the right cable.
Technical support

Questions? We help you select the right cable.

Request a quote

Related products