Fire Resistant Cables

TOXFREE® PLUS 331 ROZ1-K (AS+)

Reference specification for ROZ1-K (AS+) in the Fire Resistant Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

Open Air, Buried, In conduit

Category Fire Resistant Cables
Brand TOXFREE® (reference)
Voltage 0,6/1 kV
Conductor Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
Standards IEC 60502-1
Applications Open Air, Buried, In conduit
Updated 2026-07-28

Technical overview

Key product information for comparison, engineering review and quotation preparation.

Product description

Reference specification for ROZ1-K (AS+) in the Fire Resistant Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

MaterialCopper, class 5 (flexible)
ConductorElectrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
InsulationMica tape + XLPE
ScreenAluminium-polyester tape 100% coverage + tinned copper drain wire
Outer SheathPolyolefin LSZH. Orange colour
Rated Voltage0,6/1 kV
Maximum Conductor Temperature90 °C
Maximum Short-Circuit Temperature250 (max. 5 s) °C
Minimum Installation Temperature0 (on cable surface) °C
Minimum Service Temperature-40 (fixed and protected installations) °C
Fire ResistancePH120 minimum 120 minutes at 840°C according to IEC 60331-2 / EN 50200 (≤20mm) and IEC 60331-1 / EN 50362 (>20mm)
Flame Non-PropagationFlame non-propagation according to EN 60332-1 and IEC 60332-1
Fire Non-PropagationFire non-propagation according to EN 60332-3 and IEC 60332-3
Halogen FreeHalogen free according to IEC 60754-1
Low Corrosive Gases EmissionLow corrosive gases emission according to EN 60754-2 and IEC 60754-2
Low Smoke EmissionLow smoke emission according to EN 61034 and IEC 61034
Light Transmittance> 60%
Minimum Bending Radius10x cable diameter
Impact ResistanceAG2 Medium severity
Chemical & Oil ResistanceAcceptable
UV ResistanceYes, according to EN 50618
Water ResistanceAD5 Jets
Installation ConditionsOpen Air, Buried, In conduit
Standards (According To)IEC 60502-1
Standards and ApprovalsCE, RoHS
Typical ApplicationsEmergency circuits, Variable Frequency Drive Motors, Industrial facilities

Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.

Key characteristics

Electrical performance 0,6/1 kV
Conductor Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
Standards IEC 60502-1
Applications Open Air, Buried, In conduit
Visits 1

Typical applications

Use-case guidance to understand where this product fits best.

TOXFREE® PLUS 331 ROZ1-K (AS+)

Open Air

Reference application: Open Air.

TOXFREE® PLUS 331 ROZ1-K (AS+)

Buried

Reference application: Buried.

TOXFREE® PLUS 331 ROZ1-K (AS+)

In conduit

Reference application: In conduit.

Why choose this cable

Service and manufacturing advantages that support the product decision.

Quality

Quality

Stable manufacturing and dependable delivery quality.

Engineering

Engineering

Practical cable solutions for project-specific use cases.

Value

Value

Balanced cost and product performance for long-term projects.

Support

Support

Fast response before delivery and after project deployment.

Product FAQs

Use these quick answers to help technical and commercial teams align faster.

Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.

Questions? We help you select the right cable.
Technical support

Questions? We help you select the right cable.

Request a quote

Related products