Henan Donglian Cable Co., Ltd.
Fire Resistant Cables
Cables

Fire Resistant Cables

Reference product range for fire resistant cables, organized for technical comparison and project enquiries.

Fire Resistant Cables

TOXFREE® LSZH FIRE ALARMS Z1OZ1-K (AS+)

Reference specification for Z1OZ1-K (AS+) in the Fire Resistant Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

Open Air, In conduit, Fixed installations

Category Fire Resistant Cables
Brand TOXFREE® (reference)
Voltage 300/500 V
Conductor Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
Standards UNE 211025
Applications Open Air, In conduit, Fixed installations
Updated 2026-07-28

Technical overview

Key product information for comparison, engineering review and quotation preparation.

Product description

Reference specification for Z1OZ1-K (AS+) in the Fire Resistant Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

MaterialCopper, class 5 (flexible)
ConductorElectrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
InsulationMica tape + Polyolefin LSZH
ScreenAluminium-polyester tape 100% coverage + drain wire
Outer SheathPolyolefin LSZH. Red colour
Rated Voltage300/500 V
Maximum Conductor Temperature70 °C
Maximum Short-Circuit Temperature160 (max. 5 s) °C
Minimum Service Temperature-40 (fixed and protected installations) °C
Fire ResistancePH120 minimum 120 minutes at 840°C according to IEC 60331-2 and EN 50200
Flame Non-PropagationFlame non-propagation according to EN 60332-1 and IEC 60332-1
Fire Non-PropagationFire non-propagation according to EN 50399
CPR ClassificationCca-s1a,d1,a1 according to EN 50575
Halogen FreeHalogen free according to IEC 60754-1
Low Corrosive Gases EmissionLow corrosive gases emission according to EN 60754-2 and IEC 60754-2
Low Smoke EmissionLow smoke emission according to EN 61034 and IEC 61034
Light Transmittance> 80%
Minimum Bending Radius10x cable diameter
Chemical & Oil ResistanceAcceptable
Water ResistanceAD3 Sprays
Installation ConditionsOpen Air, In conduit, Fixed installations
Standards (According To)UNE 211025
Standards and ApprovalsCE, RoHS
Typical ApplicationsEmergency circuits, Fire Detection and Alarm systems, High-occupancy buildings

Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.

Key characteristics

Electrical performance 300/500 V
Conductor Electrolytic annealed copper, class 5 (flexible) according to EN 60228 and IEC 60228
Standards UNE 211025
Applications Open Air, In conduit, Fixed installations
Visits 1

Typical applications

Use-case guidance to understand where this product fits best.

TOXFREE® LSZH FIRE ALARMS Z1OZ1-K (AS+)

Open Air

Reference application: Open Air.

TOXFREE® LSZH FIRE ALARMS Z1OZ1-K (AS+)

In conduit

Reference application: In conduit.

TOXFREE® LSZH FIRE ALARMS Z1OZ1-K (AS+)

Fixed installations

Reference application: Fixed installations.

Why choose this cable

Service and manufacturing advantages that support the product decision.

Quality

Quality

Stable manufacturing and dependable delivery quality.

Engineering

Engineering

Practical cable solutions for project-specific use cases.

Value

Value

Balanced cost and product performance for long-term projects.

Support

Support

Fast response before delivery and after project deployment.

Product FAQs

Use these quick answers to help technical and commercial teams align faster.

Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.

Questions? We help you select the right cable.
Technical support

Questions? We help you select the right cable.

Request a quote

Related products

Previous: 没有了! Next: TOXFREE® LSZH RZ1C4Z1-K (AS+)