Reference product range for aluminium cables, organized for technical comparison and project enquiries.
Open Air. Buried. In conduit.
Key product information for comparison, engineering review and quotation preparation.
Reference specification for RV Al / U-1000 AR2V in the Aluminium Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
| Material | Aluminium, class 2 |
|---|---|
| Conductor | Aluminium, class 2 according to EN 60228 and IEC 60228 |
| Insulation | Cross-linked polyethylene type XLPE according to IEC 60502-1 |
| Outer Sheath | PVC (flexible). Black colour |
| Rated Voltage | 0.6/1 kV |
| Maximum Conductor Temperature | 90 °C |
| Maximum Short-Circuit Temperature | 250 (max. 5 s) °C |
| Minimum Service Temperature | -40 (fixed and protected installations) °C |
| Flame Non-Propagation | Flame non-propagation according to EN 60332-1 / IEC 60332-1 |
| CPR Classification | Eca according to EN 50575 |
| Reduced Halogens | Reduced halogens, Chlorine < 15%. Category C2 according to NF C 32-070 |
| Minimum Bending Radius | 5x cable diameter |
| Impact Resistance | AG3 High severity (≤5J) |
| Chemical & Oil Resistance | Good |
| UV Resistance | UV Resistant according to UNE 211605 and NF C 32-321 |
| Water Resistance | AD8 Submersion |
| Installation Conditions | Open Air. Buried. In conduit. |
| Standards (According To) | IEC 60502-1, UNE 21123-2, UNE HD 603-5N, XP C 32-321 |
| Standards and Approvals | AENOR, NF-USE, RoHS, CE |
| Typical Applications | Power distribution, Industrial facilities, Buried PV installations |
Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.
Use-case guidance to understand where this product fits best.
Reference application: Open Air. Buried. In conduit..
Reference application: Aluminium Cables.
Reference application: Aluminium Cables.
Service and manufacturing advantages that support the product decision.
Stable manufacturing and dependable delivery quality.
Practical cable solutions for project-specific use cases.
Balanced cost and product performance for long-term projects.
Fast response before delivery and after project deployment.
Use these quick answers to help technical and commercial teams align faster.
Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.