Henan Donglian Cable Co., Ltd.
LSZH Cables
Cables

LSZH Cables

Reference product range for lszh cables, organized for technical comparison and project enquiries.

LSZH Cables

TOXFREE® LSZH FR-N1X1G1 Flex

Reference specification for FR-N1X1G1 Flex in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

Open Air, Buried, In conduit

Category LSZH Cables
Brand TOXFREE® (reference)
Voltage 0,6/1 kV
Conductor Electrolytic annealed copper, class 5 (flexible), according to EN 60228 and IEC 60228
Standards AENOR, KEMA-KEUR, RoHS, CE
Applications Open Air, Buried, In conduit
Updated 2026-07-28

Technical overview

Key product information for comparison, engineering review and quotation preparation.

Product description

Reference specification for FR-N1X1G1 Flex in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.

MaterialCopper, class 5 (flexible)
ConductorElectrolytic annealed copper, class 5 (flexible), according to EN 60228 and IEC 60228
InsulationCross-linked polyethylene type XLPE according to IEC 60502-1 and type DIX-3 according to HD 603
Outer SheathLow Smoke Halogen Free polyolefin, type ST8 according to IEC 60502-1. Green colour.
Rated Voltage0,6/1 kV
Maximum Conductor Temperature90 °C
Maximum Short-Circuit Temperature250 (max. 5 s) °C
Minimum Service Temperature-40 (fixed and protected installations) °C
Minimum Installation and Handling Temperature0 °C
Flame Non-PropagationFlame non-propagation according to IEC 60332-1 / EN 60332-1
Fire Non-PropagationFire non-propagation according to NF EN IEC 60332-3 and EN 50399
CPR ClassificationB2ca-s1a,d1,a1 or Cca-s1a,d1,a1 (according to cross-section) according to EN 50575
Halogen FreeLow Smoke Halogen Free according to EN 60754-1 / IEC 60754-1
Low Smoke EmissionLow smoke emission according to EN 61034 / IEC 61034
Light Transmittance> 80%
Low Corrosive Gases EmissionLow corrosive gases emission according to EN 60754-2 / IEC 60754-2
Minimum Bending Radius5x cable diameter
Impact ResistanceAG2 Medium severity
Chemical & Oil ResistanceAcceptable
UV ResistanceUV Resistant according to EN 50618
Water ResistanceAD8 Submersion
Installation ConditionsOpen Air, Buried, In conduit
Standards (Based On / According To)NF C 32-323 / NF C15-100, IEC 60502-1
Standards and ApprovalsAENOR, KEMA-KEUR, RoHS, CE
Typical ApplicationsIndustrial facilities, Public places (hospitals, schools, museums, airports, bus terminals, shopping centres, offices, laboratories), ERP, IGH, Underground stations, Data Centers

Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.

Key characteristics

Electrical performance 0,6/1 kV
Conductor Electrolytic annealed copper, class 5 (flexible), according to EN 60228 and IEC 60228
Standards AENOR, KEMA-KEUR, RoHS, CE
Applications Open Air, Buried, In conduit
Visits 1

Typical applications

Use-case guidance to understand where this product fits best.

TOXFREE® LSZH FR-N1X1G1 Flex

Open Air

Reference application: Open Air.

TOXFREE® LSZH FR-N1X1G1 Flex

Buried

Reference application: Buried.

TOXFREE® LSZH FR-N1X1G1 Flex

In conduit

Reference application: In conduit.

Why choose this cable

Service and manufacturing advantages that support the product decision.

Quality

Quality

Stable manufacturing and dependable delivery quality.

Engineering

Engineering

Practical cable solutions for project-specific use cases.

Value

Value

Balanced cost and product performance for long-term projects.

Support

Support

Fast response before delivery and after project deployment.

Product FAQs

Use these quick answers to help technical and commercial teams align faster.

Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.

Questions? We help you select the right cable.
Technical support

Questions? We help you select the right cable.

Request a quote

Related products