Reference product range for lszh cables, organized for technical comparison and project enquiries.
Open Air, Buried, In conduit
Key product information for comparison, engineering review and quotation preparation.
Reference specification for FR-N1X1G1 Flex in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
| Material | Copper, class 5 (flexible) |
|---|---|
| Conductor | Electrolytic annealed copper, class 5 (flexible), according to EN 60228 and IEC 60228 |
| Insulation | Cross-linked polyethylene type XLPE according to IEC 60502-1 and type DIX-3 according to HD 603 |
| Outer Sheath | Low Smoke Halogen Free polyolefin, type ST8 according to IEC 60502-1. Green colour. |
| Rated Voltage | 0,6/1 kV |
| Maximum Conductor Temperature | 90 °C |
| Maximum Short-Circuit Temperature | 250 (max. 5 s) °C |
| Minimum Service Temperature | -40 (fixed and protected installations) °C |
| Minimum Installation and Handling Temperature | 0 °C |
| Flame Non-Propagation | Flame non-propagation according to IEC 60332-1 / EN 60332-1 |
| Fire Non-Propagation | Fire non-propagation according to NF EN IEC 60332-3 and EN 50399 |
| CPR Classification | B2ca-s1a,d1,a1 or Cca-s1a,d1,a1 (according to cross-section) according to EN 50575 |
| Halogen Free | Low Smoke Halogen Free according to EN 60754-1 / IEC 60754-1 |
| Low Smoke Emission | Low smoke emission according to EN 61034 / IEC 61034 |
| Light Transmittance | > 80% |
| Low Corrosive Gases Emission | Low corrosive gases emission according to EN 60754-2 / IEC 60754-2 |
| Minimum Bending Radius | 5x cable diameter |
| Impact Resistance | AG2 Medium severity |
| Chemical & Oil Resistance | Acceptable |
| UV Resistance | UV Resistant according to EN 50618 |
| Water Resistance | AD8 Submersion |
| Installation Conditions | Open Air, Buried, In conduit |
| Standards (Based On / According To) | NF C 32-323 / NF C15-100, IEC 60502-1 |
| Standards and Approvals | AENOR, KEMA-KEUR, RoHS, CE |
| Typical Applications | Industrial facilities, Public places (hospitals, schools, museums, airports, bus terminals, shopping centres, offices, laboratories), ERP, IGH, Underground stations, Data Centers |
Reference source: Top Cable public product page. This local entry is a technical reference and does not imply manufacturing ownership of the referenced trademark.
Use-case guidance to understand where this product fits best.
Reference application: Open Air.
Reference application: Buried.
Reference application: In conduit.
Service and manufacturing advantages that support the product decision.
Stable manufacturing and dependable delivery quality.
Practical cable solutions for project-specific use cases.
Balanced cost and product performance for long-term projects.
Fast response before delivery and after project deployment.
Use these quick answers to help technical and commercial teams align faster.
Confirm voltage, conductor construction, installation conditions, required standards and cable sizing for the specific project.
Where the source provides a public datasheet, use the download button and verify that it is the current revision.
Send the reference model and project requirements to the sales team for an equivalent-product review and quotation.
Reference specification for N2XH in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for N2XH flex 1,8/3kV in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.
Reference specification for YMz1Kf in the LSZH Cables range. Confirm final construction, standards and sizing for the actual project before ordering.